Talking Architecture & Design Podcast (Episode 228) - Water, so fundamental to life, yet so complex Listen Now
My shortlist (0 item)
    Australian Panels

    TERMIflor by STRUCTAflor

    STRUCTAflor® TERMIflor® is termite protected structural grade particleboard sheet flooring, providing cost-effective long-term defence against termite damage.

    FEATURES & BENEFITS: 

    • Protected against termite damage – treated in accordance with Australian Standards
    • STRUCTAflor® TERMIflor® has a Red coloured edge wax to identify floor type.
    • STRUCTAflor® TERMIflor® has unique colour-coded tongues to identify thickness;
      - Yellow Tongue - 19mm for joist centres up to 450mm
      - Red Tongue - 22mm for joist centres up to 600mm
      - Blue Tongue - 25mm heavy duty for joist centres up to 600mm
    • Inbuilt moisture protection
      - Wax impregnated throughout
      - Edge wax coated
      - No need to seal uncut edges
    • Third party certified by the Engineered Wood Products Association of Australasia
    • Produced in Australia from sustainably grown Australian plantation pine
    • This product comes with a guarantee with Koppers. Conditions apply. See www.kopperspc.com.au for details.
    • Manufactured from Australian plantation pine
       

    COMPLIANCE: 

    Produced to meet Australian/New Zealand Standard AS/NZS1860.1 Particleboard Flooring Part 1: Specifications and independently tested and accredited by The Engineered Wood Products Association of Australasia (EWPAA).

    H2 Termite Treatment Brand Numbers

    • Gympie Plant 445 70 H2
    • Oberon Plant 135 70 H2
    • Mount Gambier Plant 638 70 H2

    Formaldehyde Emission

    Formaldehyde emission meets the E1 standard requirement of ≤1.5 mg/L when tested in accordance with Australian/New Zealand Standard AS/NZS 4266.16:2004 Method of test 16: Formaldehyde emission - Desiccator method.
     

    RANGE:

    range-table.jpg


    INDUSTRY INFORMATION:

    Environmental credentials are detailed in the Wood Solutions Environmental Product Declaration: Particleboard.
     

    TECHNICAL NOTES:

    Installation Instructions

    Please refer to the STRUCTAflor® Installation and Design Manual.

    AS1860.2 Particleboard Flooring Part 2: Installation sets out the minimum performance requirements for the installation of particleboard flooring which are acceptable to building authorities in Australia.

    Further information is also available in the EWPAA Particleboard Structural Flooring Design Manual.

    Design Parameters and Safe Loads

    Design parameters information and safe load tables are included in the EWPAA Particleboard Structural Flooring Design Manual.

    Thermal Insulation

    The thermal conductivity of STRUCTAflor® is 0.12W/mK. Thermal resistance (R-values) calculated in accordance with the relevant provisions of Australian Standard AS/NZS4589.1 for the nominated thicknesses are:

    • Yellow Tongue 19mm R0.16
    • Red Tongue 22mm R0.18
    • Blue Tongue 25mm R0.21
       

    Exposure, Storage & Handling

    STRUCTAflor® may be exposed to the weather for up to three months, however it is always advisable to enclose the building as soon as possible after laying the floor. Any ponded water should be removed as soon as practicable. This can be achieved by drilling holes of 3mm maximum diameter at not less than 1 metre spacing through the floor where ponding occurs and sweeping water away.

    When storing outside ensure packs are kept clear of the ground. Cover with waterproof sheeting laid on timber battens so that air circulates freely between the waterproof cover and the product. Handle and stack with care to avoid damage.

    Safety

    Gloves, dust masks and glasses should be worn at all times when working with timber. Please refer to Material Safety Data Sheet (MSDS) for full details.

    Waste Disposal

    Off-cuts can be disposed of as normal landfill waste. Do not burn treated timbers. Please refer to above Material Safety Data Sheet (MSDS) for full details.

     

    Please correct the errors and try again.

    Contact Australian Panels

    CONTACT
    Back to Top